Product Center

Contact Us

Contact person: Mr. Wang




No. 1, Building 1, Zhenrong Road, Wusha, Chang'an Town, Dongguan City, Guangdong Province


+
  • 图片 16.jpg
  • 图片 15.jpg
  • 图片 17.jpg
  • 图片 18.jpg

High and low temperature and humidity test chamber

The product is used to simulate environmental high and low temperature storage tests, high and low temperature cycle tests, temperature and humidity tests (alternating damp heat, constant damp heat), and high temperature and high humidity aging tests.

Category:

High and low temperature test chamber

Keyword:

Kexun



Product Introduction

Product Specifications: Supports standard volume selection of 26L~1500L and non-standard customization

Product Introduction: The product is used to simulate environmental high and low temperature storage tests, high and low temperature cycle tests, temperature and humidity tests (alternating wet heat, constant wet heat), and high temperature and high humidity aging tests.

Product Alias: High temperature and high humidity test chamber, alternating wet heat chamber, humidity test chamber, constant temperature and humidity test chamber, temperature and humidity test chamber, constant humidity and heat aging chamber, double 85 test chamber

High and Low Temperature (Wet Heat) Test Chamber: The product is superior to MIL, STD, GB, GJB, JIS, JEDEC, and IEC test standards. It has an extremely wide temperature and humidity control range and extremely high control accuracy. It supports standard volume selection of 26~1500L and other non-standard customized models. It can simulate environmental high (low) temperature tests, high and low temperature combined cycles, humidity, rapid temperature changes, temperature and humidity combined cycles (alternating wet heat), constant temperature and humidity, high temperature and high humidity "double 85", "double 95", or "double 98" and other test conditions.

I. Application Fields: Semiconductor chips, scientific research institutions, quality inspection, new energy, optoelectronic communication, aerospace military industry, automotive industry, LCD display, medical and other technological industries, such as:

1. Electronics and Electrical Industry: Testing the performance of electronic components, integrated circuits, and circuit boards under high and low temperature and wet heat conditions to ensure that products work normally in various environments.

2. Automotive Industry: Conducting high and low temperature and wet heat cycle tests on automotive components such as engines, instrument panels, and batteries to evaluate their reliability and lifespan in extreme environments.

3. Aerospace: Conducting environmental simulation tests on key components of aircraft and spacecraft to ensure their performance under high-altitude, extreme temperature, and humidity conditions.

4. Materials Science: Conducting high and low temperature and wet heat tests on new materials to evaluate their physical and chemical properties, such as tensile strength, corrosion resistance, and thermal expansion.

5. Pharmaceuticals and Biotechnology: Used for drug stability testing, simulating the storage environment of drugs under different temperature and humidity conditions to ensure the effectiveness and safety of drugs within their shelf life.

6. Construction and Building Materials: Testing the performance of building materials such as concrete, steel, and wood in high and low temperature and wet heat environments to ensure the safety and durability of building structures under various climatic conditions.

7. Military and Defense: Conducting environmental simulation tests on weapon systems, communication equipment, etc., to ensure their reliability under battlefield conditions.

II. Standards Met: GB/T 2423.1-2008(IEC68-2-1),GB/T 2423.2-2008(IEC68-2-2),GB/T 2423.3-2008(IEC68-2-3),GB/T 2423.4-2008(IEC68-2—30),GJB360.8-2009(MIL-STD.202F),GJBl50.3-2009(MIL-STD-810D),GJBl50.4-2009(MIL-STD-810D),GJBl50.9-2009(MIL-STD-810D)

New servo flow control technology + innovative structural design: Equipment energy saving 45%, lifespan extended by more than 1/3.

Scientific air duct design with upper air outlet and lower air return, fast and stable temperature and humidity, high uniformity ≤1.5℃.

Load adaptive, adaptive thermal load loading capacity within the full temperature and humidity controllable range.

Some performance is superior to MIL, STD, GB, GJB, JIS, JEDEC, IEC and other test standards.

Drip-proof design on the top of the working chamber, effectively avoiding the influence of condensed water droplets on the sample test results.

*Customizable non-standard models with any specifications*

High and Low Temperature (Wet Heat) Alternating Test Chamber

Model

KS-HW-80L- A/B/D

KS-HW-100L- A/B/D

KS-HW-150L- A/B/D

KS-HW-225L- A/B/D

KS-HW-408L- A/B/D

KS-HW-1000L- A/B/D

Inner Chamber Volume (L)

80 L

100L

150 L

225 L

408 L

1000 L

Inner Chamber Dimensions
(mm)

Width W

400

500

500

600

800

1000

Depth D

400

400

500

500

600

1000

Height H

500

500

600

750

850

1000

Viewing Window Size
(mm)

Width W*Height H

210*300

210*300

214*300

280*350

360*510

360*510

Performance Indicators

Temperature Range

A:-40~+150℃,B:-20~+150℃,D:-70~+150℃(+180℃)

Humidity Range

20%~98%R.h (10%~98%R.h/5%~98%R.h are special models)

Temperature and Humidity Fluctuation

Temperature ≤±0.3℃,Humidity ≤±2.0%RH

Temperature and Humidity Uniformity

Temperature ≤1.5℃, Humidity ≤3.0%RH

Heating Rate

≥4℃/min average throughout (5~25℃/min linear/non-linear are special conditions and require customization)

Cooling rate

≥1℃/min average throughout, (3~25℃/min linear/non-linear are special conditions and require customization)

Wind speed

≤1.7m/s

Cabinet material

Inner box

SUS #304 stainless steel

Outer box

Cold-rolled steel plate + double-sided electrostatic spraying process, Kexun standard blue-gray

Insulation

Ultra-fine glass wool

Noise (dB)

≤65

Controller

7-inch color touch screen controller (with pressure, temperature and humidity, with RS-485 or RS-232 communication, USB data backup)

Cooling method

Air cooling/Water cooling

Refrigerant model

Environmentally friendly refrigerant R404A, R23

Power supply

AC 220V or (AC 380V) 50/60Hz

Weight (KG)

280

290

320

420

540

720

Power (KW)

4

4.2

6

7.5

7.5

8.5

Environmental requirements

Air cooling environment temperature requirement +5~+30℃/Water cooling environment temperature requirement +5~+40℃ (Water cooling requires a water tower or chiller)

Protection devices

1. Overtemperature protection, 2. Fan overload protection, 3. Temperature deviation alarm, 4. Compressor overpressure, overload, overheat protection, 5. Humidifier water shortage, low water level protection, 6. Heater dry burning, overload protection, 7. Water tank overflow, water shortage alarm protection, 8. Power phase loss protection, 9. Overcurrent protection, 10. Short circuit leakage protection

Standard configuration

Observation window (double-layer hollow tempered conductive glass) 1; Test hole Φ50/Φ100mm (located on the left/right) 1; Sample rack 2 layers; In-box photographic lamp (LED strip) 1; Small casters 4; Power cord 1.

Model description