Product Center

Contact Us

Contact person: Mr. Wang




No. 1, Building 1, Zhenrong Road, Wusha, Chang'an Town, Dongguan City, Guangdong Province


+
  • 图片 75.jpg
  • 图片 74.jpg
  • 图片 76.jpg

DQY High-Altitude Low-Pressure Test Chamber

The high-altitude, low-pressure test chamber is used to determine the adaptability and reliability of components, materials, instruments, equipment, or other products in (high-altitude, low-oxygen, high-cold, plateau, etc.) environments. It can also meet the requirements of high and low temperature/constant temperature and humidity tests, and detect the parameter performance of various materials after changes in extreme environments such as heat resistance, cold resistance, dryness resistance, and humidity resistance.

Category:

High and low temperature test chamber

Keyword:

Kexun



Product Introduction

Product Specifications: Inner box meets 150~3300L standard volume and other non-standard customized models

Product Use: The product high-altitude low-pressure test chamber is used to determine the adaptability and reliability of components, materials, instruments, equipment, or other products in (high altitude, low oxygen, high cold, plateau, etc.) environments. It can also meet the tests of high and low temperature/constant temperature and humidity changes, and detect the parameter performance of various materials after changes in heat resistance, cold resistance, dryness resistance, and humidity resistance in extreme environments.

Product Alias: High and low temperature low pressure test chamber, high and low temperature humidity low pressure test chamber, high altitude environmental test chamber, plateau low pressure test machine.

The KSKexun high-altitude low-pressure test chamber simulates the changes in temperature and altitude to evaluate the use and storage of electronic and electrical equipment in (high altitude, low oxygen, high cold, plateau, etc.) environments. It is widely used in the reliability testing of aerospace products, information communication, instrumentation, electrical engineering, and mechanical products.

I. Test Standards Met:

GB/T 2423.1-2008 Test A: Low temperature test method;

GJB150.1A-2A-3A-4A-9A-24A-2009 Military equipment laboratory environmental test methods.

GB/T 2423.21-2008 Test M: Low pressure test method;

GB/T 2423.25-2008 Test Z/AM: Low temperature/low pressure combined test.

GB/T 2423.26-2008 Test Z/BM: High temperature/low pressure combined test;

GB/T 2423.2-2008 Test B: High temperature test method.

GJB360A-1996 Method 105: Low pressure test;

GJB 367A-2001 "General Specifications for Military Communication Equipment" Appendix A General Environmental Test Methods.

II. Equivalent Altitude as shown in the table below ((from GB/T 2423.21-2008))

Set Pressure (KPa)

1

2

4

8

15

25

40

55

70

84

Corresponding Altitude (m)

31200

26600

22100

17600

13600

10400

7200

4850

3000

1000

1. Advanced pressure control system, small fluctuation, high stability;

2. Single compressor refrigeration system, high efficiency, low energy consumption, low operating cost;

3. Compact structure design, light weight, small footprint, easy transportation and installation;

4. Performance indicators exceed national (military) standard quality requirements;

5. Using electronic expansion valve technology and innovative control system, product energy efficiency >30%; Specifications

*Customizable non-standard models with any specification parameters

High Altitude (Altitude) Low Pressure Test Chamber

Model

KS-DQY-225L
A/B/D

KS-DQY-408L
A/B/D

KS-DQY-1000L
A/B/D

KS-DQY-1700L
A/B/D

KS-DQY-3300L
A/B/D

Internal Volume (L)

225 L

408 L

1000 L

1700 L

3300 L

Inner Chamber Dimensions
(mm)

Width W

600

800

1000

1200

1500

Depth D

500

650

1000

1200

1500

Height H

750

850

1000

1200

1500

Performance Indicators

 

Temperature Performance Indicators

Temperature Range

A: -40~+150℃, B: -20~+150℃, D: -70~+150℃

Temperature Fluctuation

≤±0.3℃ (≤±0.5℃, according to GB/T5170-1996)

Temperature Uniformity

≤2.0℃ (at normal pressure, no load)

Temperature Deviation

≤±2℃ (at normal pressure, no load)

Heating Rate

Average 3℃/min (at normal pressure, no load)
(Temperature rate 4~25℃/minute linear/non-linear requires customization for special conditions)

Cooling Rate

Average 2℃/min (at normal pressure, no load);
(Temperature rate 2~25℃/minute linear/non-linear requires customization for special conditions)

 

Humidity Performance Indicators (Optional)

Humidity Range

20%R.h~98%R.h (other special conditions require customization)

Humidity Uniformity

≤3.0%RH

Humidity Fluctuation

≤±2.0%RH

Humidity Deviation

±3.0%RH (>75%RH), ±5.0%RH (≤75%RH)

 

Pressure Performance Indicators

Pressure Range

Normal pressure~0.5KPa

Pressure Deviation

Normal pressure~40kPa: ≤±1.8kPa; 40kPa~4kPa: ≤±4.5% kPa; 4kPa~1kPa: ≤±0.1kPa

Pressure Drop Time

Normal pressure→0.5kPa ≤ 45min (no load)

Pressure recovery rate

≤10kPa/min

Cabinet material

Inner box

SUS #304 stainless steel

Outer box

Cold-rolled steel plate + double-sided electrostatic spraying process

Insulation

Ultra-fine glass wool

Pressurization method

Internal pressurization

Noise

≤70 (dB)

Controller

7-inch color touch screen controller (with pressure, temperature and humidity, with RS-485 or RS-232 communication, USB data baking)

Temperature, humidity and time resolution

Temperature: 0.01℃; Humidity: 0.1%; Time: 0.01min

Cooling method

Water cooling, air cooling

Refrigerant model

Environmentally friendly refrigerant R404A, R23

Environmental requirements

Air-cooled ambient temperature requirement +5~+30℃/Water-cooled ambient temperature requirement +5~+40℃ (water cooling requires a water tower or chiller)

Power supply

AC380V±10%, 50Hz±1 three-phase four-wire + ground wire (3/N/PE), ground resistance less than 4Ω

Model description