Precautions for using a dust chamber?

The sand and dust testing chamber, also known as the dust testing chamber, simulates the destructive effects of natural wind and sand climates on products. Its primary use is to test the sealing performance of product casings, mainly for IP5X and IP6X tests as defined in the casing protection level standards. Below are some precautions for using a sand and dust testing chamber. Read on if you are interested.

Category: Industry News

The sand and dust test chamber, also known as a dust test chamber, simulates the destructive effects of natural wind and sand climates on products. Its primary use is to test the sealing performance of product casings, as specified in the standards for casing protection levels. IP5X and IP6X two levels of testing. Below, we will discuss the precautions to take when using a sand and dust test chamber. If you're interested, read on.

Why is it called a sand and dust test chamber? Because this machine simulates the destructive effects of natural wind and sand climates on products. Knowing this will be helpful in the future. This equipment is particularly important for testing casing sealing performance, especially for the two levels specified in the casing protection level standards. Many operators know there are many precautions to take when using a sand and dust test chamber; otherwise, equipment malfunctions and inaccurate test results may occur. Therefore, you must understand and know the relevant information before use. This also includes preventing operator injury. However, some newcomers to this industry are not very familiar with this aspect, so this information has been compiled to help everyone fully understand before use. The sand and dust test chamber can create a climate with vertically circulating dust. The dust used in the test can be recycled. The wind duct, etc., is made of high-grade stainless steel plates.

If the sand and dust test chamber malfunctions, stop it immediately and check. Only after identifying the cause and resolving the malfunction can the test chamber continue testing. In addition, if you hear any unusual noises during operation, stop the machine and check. Only after identifying and resolving the malfunction can you restart the machine to avoid affecting the service life of the sand and dust test chamber. If the instrument does not light up when the test chamber is turned on, check if the power supply is normal. Keep the exterior of the sand and dust test chamber clean; avoid external impacts; when moving the sand and dust test chamber, avoid dropping, impacting, or scratching it. Before using the equipment, check if the fan is working properly and if the dust is dry. Avoid tilting the sand and dust test chamber; do not allow chemicals to come into contact with the equipment; to ensure stable performance, the ambient temperature should be between 15 and 25 degrees Celsius, and the relative humidity should be less than 85% . Keep the laboratory dry; check the circuit control system before each startup; confirm the power supply and grounding; ensure that the equipment's power cord is properly connected according to specifications and is grounded; prohibit non-professionals from operating this equipment.

This is an introduction to the sand and dust test chamber. If you find this helpful, you can check other articles on this site.